交付对齐终稿: 离开分档{60,32,21,14}按SENUP标贴OFF(现场确认)对齐 + 全部文档同步

This commit is contained in:
wangfq
2026-08-28 11:55:32 +08:00
parent 1c8cd6a8a0
commit 9e0c6a40d2
3 changed files with 22 additions and 22 deletions
+3 -3
View File
@@ -50,18 +50,18 @@
- 进入:`CAPVD < Origin dlt`3 次确认),`dlt = Origin×SensTable[SENS]>>16`
- 离开:**简单滞回 3 次防抖**(V2.9 起默认,`(Origindlt)<CAPVD``cnt_release≥3`);平坦性三条件(CN200910309382)代码保留在 `#if USE_FLATNESS_EXIT` 内,**默认禁用**(现场实测不理想,2026-08-28
- 离开阈值 `dlt = Origin×SensTable_1[SENS]>>16`V2.11 起恒 14 = 0.021% Δf/f,对齐 PD132T 默认 ASB=OFF
- 离开阈值 `dlt = Origin×SensTable_1[SENS]>>16`V2.11 起分档 {60,32,21,14},对齐 PD132T SENUP 标贴 OFF=出厂默认
### 3.5 灵敏度表(M1H 继承,V2.8/V2.11 调整)
```
SensTable[4] = {300, 60, 36, 20} // 进入 (Δf/f: 0.46%…0.031%, V2.11 0/1 档对齐 PD132T)
SensTable_1[4] = { 14, 14, 14, 14} // 离开恒 14V2.11 对齐 PD132T 出厂默认 ASB=OFF;原 {108,72,18,14}
SensTable_1[4] = { 60, 32, 21, 14} // 离开分档V2.11 对齐 PD132T SENUP 标贴 OFF=出厂默认;原 {108,72,18,14}
```
- `SENS = 3-(sw&0x03)`(拨码反码,与 M1H 一致)
- ⚠ V2.82026-08-27):SENS=3 最高档 10→20、9→14——现场广告杆落杆误触发(落杆机械/电磁扰动越过 0.015% 阈值)
- ⚠ V2.112026-08-28):① SENS=0/1 档进入 216/108→300/600.33%/0.16%→0.46%/0.09% Δf/f)——PD132T 客户现场替换对齐,2/3 档保持;② 离开表 {108,72,18,14}→14(对齐 PD132T ASB=OFF 的恒 14 释放;若现场 ASB=ON 需改回分档 {60,32,21,14}
- ⚠ V2.112026-08-28):① SENS=0/1 档进入 216/108→300/600.33%/0.16%→0.46%/0.09% Δf/f)——PD132T 客户现场替换对齐,2/3 档保持;② 离开表 {108,72,18,14}→{60,32,21,14}(对齐 PD132T SENUP 标贴 OFF=SET_ASB=1 的分档释放,出厂默认态;若现场 SENUP 拨 ON 需改恒 14 表
## 4. 时序/速率/周期速查(2026-08-27